• MIK-PH5022 Germany glass pH sensor

    MIK-PH5022 Germany glass pH sensor

    MIK-5022 tecLine electrodes are high-quality sensors for professional applications in process and industrial measurement technology. These electrodes are known for their use of top-quality materials and components. They are designed as combined electrodes (the glass or metal electrode and the reference electrode are combined in one shaft). A temperature probe can also be integrated as an option, depending on the type. Features

    • Zero potential point:7 ± 0.5 pH
    • Conversion coefficient: > 96%
    • Installation size: Pg13.5
    • Pressure: 1 ~ 6 Bar at 25 ℃
    • Temperature: 0 ~ 130℃ for general cables
  • MIK-DO7011 Membrane dissolved oxygen sensor

    MIK-DO7011 Membrane dissolved oxygen sensor

    MIK-DO7011 Membrane type dissolved oxygen sensor is the measure of oxygen dissolved in an aqueous solution. Polarographic measurement principle, the dissolution value depends on the temperature of the aqueous solution, pressure and salinity in solution. Features Range: DO:0-20 mg/L、0-20 ppm;Temperature:0-45℃Resolution:DO:±3% of the measured value;Temperature:±0.5℃Output signal: 4~20mATemperatureType:NTC 10k/PT1000

  • MIK-PTU8011 Turbidity Sensor

    MIK-PTU8011 Turbidity Sensor

    MIK-PTU-8011 turbidity meter based on the infrared absorption scattered light method and combined with the application of ISO7027 method, can guarantee the continuous and accurate detection of turbidity. Based on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of turbidity value. According to the usage environment, self-cleaning function can be equipped with. It assures the stability of data and reliability of performance; with the built-in self-diagnosis function, it can make sure the accurate data be delivered; besides, the installation and calibration is quite simple. Features Range: 0.01-100NTU、0.01-4000NTUResolution:Less than ± 2% of the measured valuePressure range: ≤0.4MPaEnvironment temp: 0~45℃

  • MIK-PH5019 Plastic pH sensor

    MIK-PH5019 Plastic pH sensor

    MIK-PH5019 plastic pH sensor is widely used in wastewater treatment and fields including mining and smelting, papermaking, paper pulp, textiles, petrochemical industry, process of semiconductor electronic industry and downstream engineering of biotechnology. Features

    • Zero potential point:7 ± 0.5 pH
    • Slope: > 98%
    • Installation size: 3/4NPT
    • Pressure: 1 ~ 3 Bar at 25 ℃
    • Temperature: 0 ~ 60℃ for general cables

    Tel.: +86 15867127446 (WhatApp)Email : info@Sinomeasure.com

  • MIK-PH5011 pH sensor

    MIK-PH5011 pH sensor

    MIK-PH5011 pH sensor increasing the silver ion at the reference sensor part, to enhance the stability and accuracy, suitable for general industrial waste water and discharge solutions.

    • Zero potential point: 7±0.25
    • Conversion coefficient:≥95%
    • Membrane resistance: <500Ω
    • Practical response time:< 1 min
    • Measurement range: 0–14 pH
    • Temperature compensation: Pt100/Pt1000/NTC10K
    • Temperature: 0~60℃
    • Reference: Ag/AgCl
    • Pressure resistance: 4 bar at 25 ℃
    • Thread Connection: 3/4NPT
    • Material: PPS/PC
  • MIK-PH5013A PTFE pH sensor for corrosive medium

    MIK-PH5013A PTFE pH sensor for corrosive medium

    MIK-pH-5013A pH sensor used in PH measurement is also called primary cell. The primary battery is a system whose function is to convert chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF). This electromotive force (EMF) consists of two half-cells. Features

    • Zero potential point:7 ± 0.5 pH
    • Conversion coefficient: > 95%
    • Installation size: 3/4NPT
    • Pressure: 1 ~ 4 Bar at 25 ℃
    • Temperature: 0 ~ 60℃ for general cables
  • MIK-ORP6050 ORP sensor

    MIK-ORP6050 ORP sensor

    MIK-ORP-6050 pH sensor used in ORP measurement is also called primary cell. The primary battery is a system whose function is to convert chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF). This electromotive force (EMF) consists of two half-cells. Features

    • Range:-2000~+2000 mV
    • Installation size: 3/4NPT
    • Pressure:6 Bar at 25 ℃
    • Temperature:0 ~ 60℃ for general cables
  • MIK-TDS7002 4 Electrodes conductivity sensor

    MIK-TDS7002 4 Electrodes conductivity sensor

    MIK-TDS-7002 a variety of functions in one: conductivity EC / TDS measurement capabilities to achieve two in one, cost-effective integrated design to support the boiler water, RO water treatment, sewage treatment, pharmaceutical industry and other liquid measurement and monitoring. Features Range:10us/cm~500ms/cmResolution:±1%FSTemp compensation:NTC10K (PT1000, PT100, NTC2.252K optional)Temperature range: 0-50℃Temperature accuracy:±3℃

  • MIK-PH5050 high temperature pH sensor

    MIK-PH5050 high temperature pH sensor

    MIK-pH-5050 high temperature glass electrode used in PH measurement is also called primary cell. The primary battery is a system whose function is to convert chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF). This electromotive force (EMF) consists of two half-cells. Features

    • Zero point: 7 ± 0.5 pH
    • Installation thread3/4NPT
    • Working pressure: 1 ~ 3 Bar at 25 ℃
    • Temp: 0 to 60℃ for general cables

    Tel.: +86 15867127446 (WhatApp)Email : info@Sinomeasure.com

  • MIK-DO7016 Optical dissolved oxygen sensor

    MIK-DO7016 Optical dissolved oxygen sensor

    MIK-DO7016 Optical Dissolved Oxygen Sensor is based on luminescent optical technology. The Optical Dissolved Oxygen sensor is approved by the ASTM International Method D888-05 Features Range: 0.00 to 20.00 mg/LResolution:0.01Response time: 90% of the value in less than 60 secondsSignal interface: Modbus RS-485 (standard) and SDI-12 (option)Power supply:5 ~ 12 volts

  • MIK-TDS6012 Conductivity sensor

    MIK-TDS6012 Conductivity sensor

    MIK-TDS-6012 A variety of functions in one: conductivity EC / TDS measurement capabilities to achieve two in one, cost-effective integrated design to support the boiler water, RO water treatment, sewage treatment, pharmaceutical industry and other liquid measurement and monitoring. Features Range:0.01 electrode: 0.02~20.00us/cm
    0.1 electrode: 0.2~200.0us/cm
    1.0 electrode: 2~2000us/cm
    10.0 electrode: 0.02~20ms/cm

  • MIK-ORP6040 ORP sensor

    MIK-ORP6040 ORP sensor

    MIK-ORP-6040 pH sensor used in ORP measurement is also called primary cell. The primary battery is a system whose function is to convert chemical energy into electrical energy. The voltage of this battery is called electromotive force (EMF). This electromotive force (EMF) consists of two half-cells. Features

    • Range:-1000~+1000 mV
    • Installation size: 3/4NPT
    • Pressure:4 Bar at 25 ℃
    • Temperature:0 ~ 60℃ for general cables
1234 Next > >> Page 1 / 4